samfurin daki-daki
Bayani
Marka: Banatton
Wurin asali: China
Nau'in: UPS na kan layi
Lambar Samfura: BNT9300-M 20 ~ 300KVA
Mataki: Mataki Uku
Waveform: Tsaftataccen igiyar ruwa
Lokacin canja wuri: 0ms
Matsakaicin ƙarfi: 0.9
Yawan aiki: 20KVA-300KVA
Kariya: gajeriyar kewayawa, sama da ƙarfin lantarki, kariyar haɗin kai
OEM/ODM: Iya
Ikon bayarwa: 5000 Piece/ Pieces per month
Marufi: Kunshin kwali ko katako ko kamar yadda kuka nema
Siffofin
Take: "Zaɓan Dama UPS don Cibiyar Bayananku: Fahimtar Kan layi, Mataki-Uku, da Tsabtace Sine Wave UPS Systems"
A zamanin dijital na yau, cibiyoyin bayanai sune ƙashin bayan kasuwanci, adana mahimman bayanai da tabbatar da ayyuka marasa kyau. Don kare waɗannan kaddarori masu mahimmanci, tsarin samar da wutar lantarki (UPS) ba ya katsewa yana da mahimmanci. Koyaya, tare da zaɓuɓɓuka marasa ƙima da ke akwai, tantance mafi kyawun UPS don cibiyar bayanan ku na iya zama ƙalubale. A cikin wannan rukunin yanar gizon, za mu nutse cikin mahimman bambance-bambance tsakanin UPS na kan layi, UPS mai hawa uku, da tsantsar sine wave UPS don taimaka muku yanke shawara.
UPS na kan layi: Hakanan aka sani da UPS mai juyawa biyu, tsarin UPS na kan layi yana ba da mafi girman matakin kariya daga hargitsin wuta. Suna ci gaba da juyar da wutar AC zuwa wutar DC kuma suna sake dawowa, suna tabbatar da sauyi mara kyau yayin katsewar wutar lantarki. Wannan ya sa su zama masu dacewa don cibiyoyin bayanai, inda ko da ƙaramar wutar lantarki na iya haifar da lalata bayanai ko lalacewar hardware.
UPS-Uku-Uku: An tsara shi don manyan cibiyoyin bayanai da aikace-aikacen masana'antu, tsarin UPS na uku-uku suna da ikon ɗaukar nauyin wutar lantarki mafi girma da kuma samar da sakewa don tabbatar da ayyukan da ba a yanke ba. Suna da mahimmanci ga wurare tare da manyan raƙuman sabar uwar garke da kayan aiki da ke buƙatar ƙarfin mataki uku.
Pure Sine Wave UPS: Tsabtace Sine Wave Tsarukan UPS suna samar da tsaftataccen wutar lantarki, barga mai ƙarfi wanda ke kwafin wutar lantarki da tabbatar da dacewa da kayan lantarki masu mahimmanci. Suna da fa'ida musamman ga cibiyoyin bayanai waɗanda ke ɗauke da sabar, ajiya da kayan aikin sadarwar da ke da saurin lalacewa daga murɗawar jituwa da jujjuyawar wutar lantarki.
Lokacin zabar UPS don cibiyar bayanan ku, yana da mahimmanci a yi la'akari da takamaiman buƙatun wuta, ƙarfin kaya, da mahimmancin kayan aiki masu kariya. Bugu da ƙari, ya kamata a yi la'akari da abubuwa kamar haɓakawa, buƙatun kiyayewa da ingancin makamashi don tabbatar da maganin abin dogara kuma yana da tsada.
A UPS 230V, muna ba da cikakken tsarin tsarin UPS, wanda aka keɓance don saduwa da buƙatu daban-daban na cibiyoyin bayanai. Ƙwararrun ƙwararrunmu za su iya taimaka muku zaɓi mafi dacewa da mafita na UPS da ba da tallafi mai gudana don tabbatar da ci gaba da aiki na kayan aikin ku mai mahimmanci.
A taƙaice, saka hannun jari a daidai tsarin UPS yana da mahimmanci don kiyaye mutunci da amincin cibiyar bayanan ku. Ta hanyar fahimtar bambance-bambance tsakanin UPS na kan layi, UPS mai hawa uku, da tsattsauran tsarin UPS na sine, za ku iya yanke shawarar da aka sani waɗanda suka dace da buƙatun kayan aikin ku na musamman.



Karamin Bayani
1. A cikin lokacin garanti injin yana da matsala, tuntuɓi ma'aikatan tallace-tallace, za mu kasance da alhakin sabis na abokin ciniki.
2. Ya wuce lokacin garanti, aiki mara kyau da lalacewa ta mutum, har yanzu za mu ba da taimako da tallafi, za mu samar da kayan aiki a farashin farashi.
3. Bisa ga bukatun abokin ciniki, za mu iya samar da rashin daidaituwa, amma farashin zai iya zama dan kadan fiye da na'ura na gargajiya.
Aikace-aikace

Cibiyar sarrafa bayanai, The host system, Computer server, Medical, Traffic, Electricity, IT, Industrial da sauran masana'antu.
Layin Samar da Masana'antu



Marufi

Ma'aunin Fasaha
MISALI | BNT990-M | BNT9150/180-M | BNT9300-M | |
Ƙarfin Ƙarfi | Ƙarfin Majalisar | 20-90kVA / 20-90kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW | 30-300kVA / 30-300kW |
Ƙarfin Module PPwer ɗaya | 20kVA / 20kW, 25kVA / 25kW, 30kVA / 30kW | |||
MAX. Module Power NO. | 3 | 5/6 | 10 | |
INPUT | ||||
Babban shigarwar | Nau'in Wutar Lantarki (Vac) | 380/400/415 | ||
Wutar Lantarki (Vac) | 138 ~ 485Vac; 305 ~ 485Vac lodi, 138 ~ 305Vac lodi | |||
Mataki | 3-phase in / 3-phase out | |||
Mitar Suna (Hz) | 40-70 | |||
Factor Power | ≥0.99 | |||
Harmonic Distortion (THDi) | ≤3% (100% kaya) | |||
Ketare Shigar | Nau'in Wutar Lantarki (Vac) | 380/400/415 | ||
Wutar Lantarki (Vac) | 220Vac:25%(+10%+15%+20%) | |||
230 Wuta: 20% (+ 10% + 15%) | ||||
240 Wuta: 15% (+10%); -45% (-10%, -20%, -30%) | ||||
Mataki | 3-phase in / 3-phase out | |||
Wutar Wuta a ciki | EE | |||
Kewaya Baya Ban ruwa | EE | |||
Shigar Generator | EE | |||
FITARWA | ||||
Voltage (Vac) | 380/400/415± 1% | |||
Halin wutar lantarki | 1 | |||
Mitar (Hz) | Yanayin AC | ± 1% / ± 2% / 4% / ± 5% / ± 10% | ||
Yanayin baturi | (50/60±0.1%)Hz | |||
Waveform | Tsabtace Sinewave | |||
Factor Crest Mai Amincewa | 3:01 | |||
Harmonic Distortion(THDV) | ≤2% (100% Load Load); ≤3% (100% Load ɗin da ba na layi ba) | |||
Lokacin Canjawa (ms) | 0 | |||
inganci(%) | 95.50% | |||
Iyawa mai yawa | 1 hour don 110%, 10mins don 125%, 1 min don 150%, 200ms don> 150% | |||
BATURE | ||||
Matsakaicin Cajin Yanzu (A) | 18 | |||
Wutar Wutar Lantarki | ± 180V / ± 192V / 204V / 216V / ± 228V / 240 / ± 252 / ± 264 / ± 276 / ± 288 / ± 300Vdc | |||
(30/32/34/36/38/40/42/44/46/48/50 inji mai kwakwalwa) | ||||
Muhalli | ||||
Yanayin Aiki | 0 ℃ ~ 40 ℃ | |||
Ajiya Zazzabi | -25 ℃ ~ 55 ℃ | |||
Danshi na Dangi | 0 ~ 95% | |||
Tsayi | ||||
Matsayin Amo (dB) | ||||
NA JIKI | ||||
Girma (D x W x H) mm | UPS Majalisar | 600×850×1350 | 600×850×1350 600×850×1550 | 600×850×2000 |
Module | 440×620×86 | |||
Net Weight(kg) | UPS Majalisar | 140 | 155/170 | 290 |
Module | 21 | |||