Kwararriyar China PF=0.9 Modular UPS Onduleur Modular UPS 150kVA 250kVA 500kVA
Yanzu muna da ƙwararrun ƙwararrun ƙwararrun ƙwararru don samar da ingantattun ayyuka ga mabukatan mu. Mu sau da yawa muna bin ka'idodin daidaitaccen abokin ciniki, cikakkun bayanai-mai da hankali ga ƙwararrun China PF = 0.9 Modular UPS Onduleur Modular UPS 150kVA 250kVA 500kVA, Yin ƙoƙari don samun ci gaba mai ci gaba bisa ga inganci mai kyau, aminci, mutunci, da cikakkiyar fahimta game da kuzarin sashe.
Yanzu muna da ƙwararrun ƙwararrun ƙwararrun ƙwararru don samar da ingantattun ayyuka ga mabukatan mu. Mu sau da yawa muna bin ka'idojin abokin ciniki-daidaitacce, cikakkun bayanai-mai da hankali gaChina UPS da Online UPS, Samfuran mu sun sami kyakkyawan suna a kowane ɗayan ƙasashe masu alaƙa. Domin kafa kamfanin mu. mun dage kan samar da sabbin hanyoyin samar da mu tare da tsarin gudanarwa na zamani na baya-bayan nan, muna jawo hazaka masu yawa a cikin wannan masana'antar. Muna ɗaukar maganin ingancin inganci a matsayin mafi mahimmancin halayenmu.
Bayani
Marka: Banatton
Wurin asali: China
Nau'in: UPS na kan layi
Lambar Samfura: BNT9300-M 20 ~ 300KVA
Mataki: Mataki Uku
Waveform: Tsaftataccen igiyar ruwa
Lokacin canja wuri: 0ms
Matsakaicin ƙarfi: 0.9
Yawan aiki: 20KVA-300KVA
Kariya: gajeriyar kewayawa, sama da ƙarfin lantarki, kariyar haɗin kai
OEM/ODM: Iya
Ikon bayarwa: 5000 Piece/ Pieces per month
Marufi: Kunshin kwali ko katako ko kamar yadda kuka nema
Siffofin



Karamin Bayani
1. A cikin lokacin garanti injin yana da matsala, tuntuɓi ma'aikatan tallace-tallace, za mu kasance da alhakin sabis na abokin ciniki.
2. Ya wuce lokacin garanti, aiki mara kyau da lalacewa ta mutum, har yanzu za mu ba da taimako da tallafi, za mu samar da kayan aiki a farashin farashi.
3. Bisa ga bukatun abokin ciniki, za mu iya samar da rashin daidaituwa, amma farashin zai iya zama dan kadan fiye da na'ura na gargajiya.
Aikace-aikace

Cibiyar sarrafa bayanai, The host system, Computer server, Medical, Traffic, Electricity, IT, Industrial da sauran masana'antu.
Layin Samar da Masana'antu
Marufi

Yanzu muna da ƙwararrun ƙwararrun ƙwararrun ƙwararru don samar da ingantattun ayyuka ga mabukatan mu. Mu sau da yawa muna bin ka'idodin daidaitaccen abokin ciniki, cikakkun bayanai-mai da hankali ga ƙwararrun China PF = 0.9 Modular UPS Onduleur Modular UPS 150kVA 250kVA 500kVA, Yin ƙoƙari don samun ci gaba mai ci gaba bisa ga inganci mai kyau, aminci, mutunci, da cikakkiyar fahimta game da kuzarin sashe.
Kwararrun kasar SinChina UPS da Online UPS, Samfuran mu sun sami kyakkyawan suna a kowane ɗayan ƙasashe masu alaƙa. Domin kafa kamfanin mu. mun dage kan samar da sabbin hanyoyin samar da mu tare da tsarin gudanarwa na zamani na baya-bayan nan, muna jawo hazaka masu yawa a cikin wannan masana'antar. Muna ɗaukar maganin ingancin inganci a matsayin mafi mahimmancin halayenmu.
| MISALI | BNT990-M | BNT9150/180-M | BNT9300-M | |
| Ƙarfin Ƙarfi | Ƙarfin Majalisar | 20-90kVA / 20-90kW | 25-150kVA / 25-150kW 30-180kVA / 30-180kW | 30-300kVA / 30-300kW |
| Ƙarfin Module PPwer ɗaya | 20kVA / 20kW, 25kVA / 25kW, 30kVA / 30kW | |||
| MAX. Module Power NO. | 3 | 5/6 | 10 | |
| INPUT | ||||
| Babban shigarwar | Nau'in Wutar Lantarki (Vac) | 380/400/415 | ||
| Wutar Lantarki (Vac) | 138 ~ 485Vac; 305 ~ 485Vac lodi, 138 ~ 305Vac lodi | |||
| Mataki | 3-phase in / 3-phase out | |||
| Mitar Suna (Hz) | 40-70 | |||
| Factor Power | ≥0.99 | |||
| Harmonic Distortion (THDi) | ≤3% (100% kaya) | |||
| Ketare Shigar | Nau'in Wutar Lantarki (Vac) | 380/400/415 | ||
| Wutar Lantarki (Vac) | 220Vac:25%(+10%+15%+20%) | |||
| 230 Wuta: 20% (+ 10% + 15%) | ||||
| 240 Wuta: 15% (+10%); -45% (-10%, -20%, -30%) | ||||
| Mataki | 3-phase in / 3-phase out | |||
| Wutar Wuta a ciki | EE | |||
| Kewaya Baya Ban ruwa | EE | |||
| Shigar Generator | EE | |||
| FITARWA | ||||
| Voltage (Vac) | 380/400/415± 1% | |||
| Halin wutar lantarki | 1 | |||
| Mitar (Hz) | Yanayin AC | ± 1% / ± 2% / 4% / ± 5% / ± 10% | ||
| Yanayin baturi | (50/60±0.1%)Hz | |||
| Waveform | Tsabtace Sinewave | |||
| Factor Crest Mai Amincewa | 3:01 | |||
| Harmonic Distortion(THDV) | ≤2% (100% Load Load); ≤3% (100% Load ɗin da ba na layi ba) | |||
| Lokacin Canjawa (ms) | 0 | |||
| inganci(%) | 95.50% | |||
| Iyawa mai yawa | 1 hour don 110%, 10mins don 125%, 1 min don 150%, 200ms don> 150% | |||
| BATURE | ||||
| Matsakaicin Cajin Yanzu (A) | 18 | |||
| Wutar Wutar Lantarki | ± 180V / ± 192V / 204V / 216V / ± 228V / 240 / ± 252 / ± 264 / ± 276 / ± 288 / ± 300Vdc | |||
| (30/32/34/36/38/40/42/44/46/48/50 inji mai kwakwalwa) | ||||
| Muhalli | ||||
| Yanayin Aiki | 0 ℃ ~ 40 ℃ | |||
| Ajiya Zazzabi | -25 ℃ ~ 55 ℃ | |||
| Danshi na Dangi | 0 ~ 95% | |||
| Tsayi | ||||
| Matsayin Amo (dB) | ||||
| NA JIKI | ||||
| Girma (D x W x H) mm | UPS Majalisar | 600×850×1350 | 600×850×1350 600×850×1550 | 600×850×2000 |
| Module | 440×620×86 | |||
| Net Weight(kg) | UPS Majalisar | 140 | 155/170 | 290 |
| Module | 21 | |||