Farashin farashi na 2019 500va Inverter UPS Power Supply Bank UPS Baturi Stanby UPS

Takaitaccen Bayani:

Marka: Banatton
Wurin asali: China
Nau'in: UPS na kan layi
Lambar Samfura: BNT9300-M 20 ~ 300KVA
Mataki: Mataki Uku
Waveform: Tsaftataccen igiyar ruwa
Lokacin canja wuri: 0ms
Matsakaicin ƙarfi: 0.9
Yawan aiki: 20KVA-300KVA
Kariya: gajeriyar kewayawa, sama da ƙarfin lantarki, kariyar haɗin kai
OEM/ODM: Iya
Ikon bayarwa: 5000 Piece/ Pieces per month
Marufi: Kunshin kwali ko katako ko kamar yadda kuka nema


Cikakken Bayani

Ma'aunin Fasaha

Tags samfurin

Mun nace game da ka'idar haɓakawa na 'Maɗaukakin inganci, Aiki, ikhlasi da tsarin aiki na ƙasa' don samar muku da babban taimako na aiki don 2019 farashi mai 500va Inverter UPS Power Supply Bank UPS Baturi Stanby UPS, Mu maraba da ku don tambayar mu ta hanyar tuntuɓar mu ko aika wasiku da fatan ƙirƙirar haɗin gwiwa mai nasara da haɗin gwiwa.
Mun nace game da ka'idar haɓakawa na 'High ingantacciyar inganci, Aiki, ikhlasi da tsarin aiki na ƙasa-da-ƙasa' don samar muku da ingantaccen taimako na sarrafawaChina Inverter da UPS Power Supply , Kamfaninmu yana aiki ta hanyar tsarin aiki na "tushen aminci, haɗin gwiwar da aka kirkiro, mutane masu daidaitawa, haɗin gwiwar nasara-nasara". Muna fatan za mu iya samun dangantakar abokantaka da ɗan kasuwa daga ko'ina cikin duniya

Siffofin

Hoto na 4
Banatton IP20 UPS na zamani na kan layi don Cibiyar Bayanan Intanet 20kva zuwa 300Kva
Banatton IP20 UPS na zamani na kan layi don Cibiyar Bayanan Intanet 20kva zuwa 300Kva

Karamin Bayani

1. A cikin lokacin garanti injin yana da matsala, tuntuɓi ma'aikatan tallace-tallace, za mu kasance da alhakin sabis na abokin ciniki.
2. Ya wuce lokacin garanti, aiki mara kyau da lalacewa ta mutum, har yanzu za mu ba da taimako da tallafi, za mu samar da kayan aiki a farashin farashi.
3. Bisa ga bukatun abokin ciniki, za mu iya samar da rashin daidaituwa, amma farashin zai iya zama dan kadan fiye da na'ura na gargajiya.

Aikace-aikace

Banatton IP20 UPS na zamani na kan layi don Cibiyar Bayanan Intanet 20kva zuwa 300Kva

Cibiyar sarrafa bayanai, The host system, Computer server, Medical, Traffic, Electricity, IT, Industrial da sauran masana'antu.

Layin Samar da Masana'antu

Marufi

Banatton IP20 UPS na zamani na kan layi don Cibiyar Bayanan Intanet 20kva zuwa 300Kva
Mun nace game da ka'idar haɓakawa na 'Maɗaukakin inganci, Aiki, ikhlasi da tsarin aiki na ƙasa' don samar muku da babban taimako na aiki don 2019 farashi mai 500va Inverter UPS Power Supply Bank UPS Baturi Stanby UPS, Mu maraba da ku don tambayar mu ta hanyar tuntuɓar mu ko aika wasiku da fatan ƙirƙirar haɗin gwiwa mai nasara da haɗin gwiwa.
Farashin farashi na 2019China Inverter da UPS Power Supply , Kamfaninmu yana aiki ta hanyar tsarin aiki na "tushen aminci, haɗin gwiwar da aka kirkiro, mutane masu daidaitawa, haɗin gwiwar nasara-nasara". Muna fatan za mu iya samun dangantakar abokantaka da ɗan kasuwa daga ko'ina cikin duniya


  • Na baya:
  • Na gaba:

  • MISALI BNT990-M BNT9150/180-M BNT9300-M
    Ƙarfin Ƙarfi Ƙarfin Majalisar 20-90kVA / 20-90kW 25-150kVA / 25-150kW 30-180kVA / 30-180kW 30-300kVA / 30-300kW
    Ƙarfin Module PPwer ɗaya 20kVA / 20kW, 25kVA / 25kW, 30kVA / 30kW
    MAX. Module Power NO. 3 5/6 10
    INPUT
    Babban shigarwar Nau'in Wutar Lantarki (Vac) 380/400/415
    Wutar Lantarki (Vac) 138 ~ 485Vac; 305 ~ 485Vac lodi, 138 ~ 305Vac lodi
    Mataki 3-phase in / 3-phase out
    Mitar Suna (Hz) 40-70
    Factor Power ≥0.99
    Harmonic Distortion (THDi) ≤3% (100% kaya)
    Ketare Shigar Nau'in Wutar Lantarki (Vac) 380/400/415
    Wutar Lantarki (Vac) 220Vac:25%(+10%+15%+20%)
    230 Wuta: 20% (+ 10% + 15%)
    240 Wuta: 15% (+10%); -45% (-10%, -20%, -30%)
    Mataki 3-phase in / 3-phase out
    Wutar Wuta a ciki EE
    Kewaya Baya Ban ruwa EE
    Shigar Generator EE
    FITARWA
    Voltage (Vac) 380/400/415± 1%
    Halin wutar lantarki 1
    Mitar (Hz) Yanayin AC ± 1% / ± 2% / 4% / ± 5% / ± 10%
    Yanayin baturi (50/60±0.1%)Hz
    Waveform Tsabtace Sinewave
    Factor Crest Mai Amincewa 3:01
    Harmonic Distortion(THDV) ≤2% (100% Load Load); ≤3% (100% Load ɗin da ba na layi ba)
    Lokacin Canjawa (ms) 0
    inganci(%) 95.50%
    Iyawa mai yawa 1 hour don 110%, 10mins don 125%, 1 min don 150%, 200ms don> 150%
    BATURE
    Matsakaicin Cajin Yanzu (A) 18
    Wutar Wutar Lantarki ± 180V / ± 192V / 204V / 216V / ± 228V / 240 / ± 252 / ± 264 / ± 276 / ± 288 / ± 300Vdc
    (30/32/34/36/38/40/42/44/46/48/50 inji mai kwakwalwa)
    Muhalli
    Yanayin Aiki 0 ℃ ~ 40 ℃
    Ajiya Zazzabi -25 ℃ ~ 55 ℃
    Danshi mai Dangi 0 ~ 95%
    Tsayi
    Matsayin Amo (dB)
    NA JIKI
    Girma (D x W x H) mm UPS Majalisar 600×850×1350 600×850×1350 600×850×1550 600×850×2000
    Module 440×620×86
    Net Weight(kg) UPS Majalisar 140 155/170 290
    Module ashirin da daya